| Quality Standards and Classification |
- CE, ISO13485
- SFDA: Class IIb
- Anti-electroshock Degree: Class I Equipment (Internal Power Supply)
- TEMP/SpO2/NIBP: BF
- ECG/Resp: CF
|
| Application Range |
Adult/Pediatric/Neonatal (Neonatal SpO2 & Suntech Nibp) / Surgery Operating Room/ICU/CCU (Separated Parameter Board) |
| Display |
12.1" TFT Screen |
| Operating Environment |
- Temperature: 0 ~ 40°C
- Humidity: 15% ~ 80%
- Pressure: 86.0 kPa ~ 106.0kPa
|
| Transport and Storage Environment |
- Temperature: -20 ~ 55°C
- Humidity: 10% ~ 90%
- Pressure: 86.0 kPa ~ 106.0kPa
|
| Power Requirements |
- AC: 100 ~ 240V, 50Hz/60Hz
- DC: Built-in Rechargeable Battery
- Battery: 11.1V 214Wh Li-ion Battery
- 2h Operating After Full Charge
- 5min Operating After Low Battery Alarm
|
| Dimension and Weight |
- Equipment: 305*162*290mm (About); 4kg (About)
- Package: 380*350*300mm (About); 4.5kg (About)
|
| Data Storage |
- Trend Diagram/Table: 720h
- NIBP Review: 10000 Events
- Wave Review: 12h
- Alarm Review: 200 Alarm Events
- Supports Drug Concentration Titration Analysis
|
| ECG |
- 5 Leads: RA, LA, LL, RL, V
- Lead Mode: I, II, III, AVR, AVL, AVF, V
- Gain: x1.25mm/mV, 2.5mm/mV, 5.0mm/mV, 10mm/mV, 20mm/mV (Error 5%)
- Sweep Speed: 6.25mm/s, 12.5mm/s, 25mm/s, 50mm/s (Errors ±10%)
- Bandwidth: Surgery 1 ~ 25Hz, Monitor 0.5 ~ 40Hz, Diagnostic 0.05 ~ 130Hz
- Sensitivity: >200 V·P-P
- CMRR ≥112dB
- Differential Input Impedance: >5M Ohm
- Electrode Offset Potential ±300mV
- Input Impedance ≥5M
- Calibration Voltage: 1mV±5%
|
| ST Segment |
- ST Segment Range: -2.0mV ~ +2.0mV
- Accuracy: Ranging -0.8mV ~ +0.8mV, Measuring Error is ±0.02mV or ±10% — The Larger Prevails
- No Definition for Other Ranges
|
| SpO2 |
- Measurement Range: 0 ~ 100%
- Resolution: 1%
- Precision: 70% ~ 100% ±2%; 0% ~ 69%: No Definition Given
|
| Pulse Rate |
- Measure/Alarm Range: 20 ~ 300bpm
- Resolution: 1bpm
- Accuracy: ±3bpm
|
| NIBP |
- Method: Oscillometry
- Measure Mode: Manual, Auto, STAT
- Measure Interval in Auto Mode: 1~5/10/15/30/60/90/120/180/240/480min
- Measure Period in STAT Mode: 5min
- Pulse Rate Range: 40 ~ 240bpm
- Measure & Alarm Range — Adult: SYS 40~280mmHg, DIA 10~220mmHg, MEAN 20~240mmHg
- Measure & Alarm Range — Pediatric: SYS 40~220mmHg, DIA 10~160mmHg, MEAN 20~170mmHg
- Measure & Alarm Range — Neonatal: SYS 40~135mmHg, DIA 10~100mmHg, MEAN 20~110mmHg
- Static Pressure Measurement Range: 0 ~ 300mmHg, Accuracy 3mmHg
- Resolution: 1mmHg
- Max. Mean Error: 5mmHg; Max. Standard Deviation: 8mmHg
- Overpressure Protection — Adult: 300mmHg, Pediatric: 240mmHg, Neonatal: 150mmHg
|
| RESP |
- Method: Impedance Between RA-LL
- Resp Impedance Range: 0.3 ~ 3
- Base Impedance Range: 200 ~ 4000
- Bandwidth: 0.3 ~ 2.5Hz
- Gain: x0.25, x0.5, x1, x2, x4
- Resp Rate Measurement Range — Adult: 0~120BrPM, Neonatal/Pediatric: 0~150BrPM
- Resolution: 1BrPM
- Accuracy: 7~150BrPM (±2BrPM); 0~6BrPM (Unspecified)
- Apnea Alarm: 10~40s
|
| TEMP |
- Channel: 2
- Measure & Alarm Range: 0 ~ 50°C
- Resolution: 0.1°C
- Accuracy (No Sensor): ±0.1°C (0~50°C), Excluding Sensor Error
|
| Standard Accessories |
- ECG Cable & Electrodes
- SpO2 Sensor
- TEMP Probe
- NIBP Cuff & Tube
- Power Cord
- Lithium-ion Battery
- User Manual
|
| Optional |
- Etco2 (Optional)
- Dual IBP (Optional)
- Nellcor SpO2 (Optional)
- Suntech Nibp (Optional)
- Recorder (Optional)
- Touch Screen (Optional)
|