Home > Our Products > IVC-200A

IVD Diagnostic

Auto Chemistry Analyzer

IVC-200A

compatibility

200 Tests/Hour, Double Reagent

Management of reagents, serum index, whole process de tection, linear expansion of enzyme, blank deduction,dirty cuvette memory , cross infection prevention, patient info- rmation memory and association input, automatic report audit, data fuzzy query, report statistics and printing, reference range grading, alarm information classification, user operation privilege classification management.

Dedicated sampling probe equipped with sensitive liquid sensor, timely feedback of reagent & sample residuals

Technical Specification

Machine Type Random access, open reagent & locked reagent (optional)
Test Speed Constant 200 tests/hour (Mono reagent or double reagent)
Test Principle Colorimetric method, turbidimetry
Test Method 1 point end, 2 point end, Fixed-Time, Kinetics
Calibration Type Linear & Nonlinear
Mixing System Mixer paddle-type mixing, effectively reducing carry-over.
Light Source Halogen lamp
Wavelength 340nm, 405nm, 450nm, 505nm, 546nm, 578nm, 630nm, 700nm (4 additional options)
Absorbance Range 0 – 4.0 Abs
Resolution 0.0001 Abs
Operating System Windows XP, Windows 7, Windows 8, Windows 10
Data Processing
  • Automatic calibration
  • Test combination
  • Effective reagent management
  • Serum index
  • Whole process detection
  • Linear enzyme expansion
  • Blank deduction
  • Dirty cuvette memory
  • Cross infection prevention
  • Patient information memory and association input
  • Automatic report audit
  • Data fuzzy query
  • Report statistics and printing
  • Reference range grading
  • Alarm information classification
  • User privilege classification management
Report Printing 6 report formats optional, supports custom report template.
Interface TCP/IP Network Interface
Power Supply AC 110/220V ±10%, 50/60Hz, 1000VA
Water Consumption 8 L/hour (Maximum)
Dimensions ≤745 × 540 × 530 mm (L × W × H)
Weight ≤80 kg
Sample Tray 40 sample positions
Sample Tube Micro cup, test tube and blood collection tube can be used (Φ12–13 mm × 25–100 mm)
Sample Volume 2–30 μL (0.1 μL step)
Sample Probe Liquid surface detection, automatic liquid level tracking and collision avoidance.
Sample Barcode Sample barcode reader (Optional)
Reagent Tray 80 reagent positions (40 for R1 & 40 for R2), non-stop cooling system with Peltier pad, 24-hour cooling at 2℃–14℃, open reagent system.
Reagent Volume 20–300 μL (1 μL step)
Reagent Needle Liquid surface detection, automatic liquid level tracking and collision avoidance.
Reagent Barcode Reagent barcode reader (Optional)
Reaction Tray Single-circle reaction tray with 44 semi-permanent plastic cuvettes.
Reaction Volume 150–330 μL
Reaction Time 10 minutes
Reaction Temperature Peltier pad incubation system, 37℃ ±0.1℃

Fully-Auto Chemistry Reagents

Auto Chemistry Reagents
SNNameFull Name and MethodPack Size (ml)UnitTotal Volume (ml)
1ALTAlanine Aminotransferase (ALT) Assay Kit (L-alanine Substrate Method)R1: 40ml×4 R2: 10ml×4box200
2ASTAspartate Aminotransferase (AST) Assay Kit (Aspartate Substrate Method)R1: 40ml×4 R2: 10ml×4box200
3ALPAlkaline Phosphatase (ALP) Assay Kit (NPP Substrate-AMP Buffer Method)R1: 40ml×4 R2: 10ml×4box200
4GGTγ-Glutamyltransferase (GGT) Assay Kit (GCANA Substrate Method)R1: 40ml×4 R2: 10ml×4box200
5TBILTotal Bilirubin (TBIL) Assay Kit (Vanadate Oxidation Method)R1: 40ml×4 R2: 10ml×4box200
6DBILDirect Bilirubin (DBIL) Assay Kit (Vanadate Oxidation Method)R1: 40ml×4 R2: 10ml×4box200
7TPTotal Protein (TP) Assay Kit (Biuret Method)R: 40ml×4box160
8ALBAlbumin (ALB) Assay Kit (Bromocresol Green Method)R: 40ml×4box160
9ADAAdenosine Deaminase (ADA) Assay Kit (Peroxidase Method)R1: 40ml×2 R2: 10ml×2 (Calibrator:1ml×1,Control Level 1:1ml×1)box100
10TBATotal Bile Acid (TBA) Assay Kit (Enzymatic Cycling Method)R1: 40ml×2 R2: 10ml×2box100
11PAPrealbumin (PA) Assay Kit (Immunoturbidimetric Method)R1: 30ml×2 R2: 10ml×2box80
12LAPLeucine Aminopeptidase (LAP) Assay Kit (L-Leucine-p-nitroaniline Substrate Method)R: 40ml×2box80
13GLU-HGlucose (GLU-H) Assay Kit (Hexokinase Method)R1: 40ml×4 R2: 10ml×4box200
14FMNFructosamine (FMN) Assay Kit (Nitrotetrazolium Blue Method)R: 40ml×2 (Calibrator:1ml×1,Control Level 1:1ml×1)box80
15UREAUrea (UREA) Assay Kit (Urease-Glutamate Dehydrogenase Method)R1: 40ml×4 R2: 10ml×4box200
16CREA-ECreatinine (CREA-E) Assay Kit (Sarcosine Oxidase Method)R1: 40ml×4 R2: 10ml×4box200
17UAUric Acid (UA) Assay Kit (Uricase Method)R1: 40ml×4 R2: 10ml×4box200
18Cys-CCystatin C (Cys-C) Assay Kit (Latex-enhenced Immunoturbidimetric Method)R1: 30ml×2 R2: 10ml×2box80
19RBPRetinol-Binding Protein (RBP) Assay Kit (Latex-enhenced Immunoturbidimetric Method)R1: 30ml×2 R2: 10ml×2box80
20UMAUrine Microalbumin (UMA) Assay Kit (Immunoturbidimetric Method)R1: 30ml×2 R2: 10ml×2box80
21B2Mβ2-microglobulin (B2M) Assay Kit (Latex-enhenced Immunoturbidimetric Method)R1: 30ml×2 R2: 10ml×2box80
22α-AMYα-Amylase (α-AMY) Assay Kit (CNPG2 Substrate Method)R: 40ml×4box160
23TGTriglycerides (TG) Assay Kit (GPO-PAP Method)R1: 40ml×4 R2: 10ml×4box200
24CHOTotal Cholesterol (CHO) Assay Kit (CHOD-PAP Method)R1: 40ml×4 R2: 10ml×4box200
25LDL-CLow Density Lipoprotein Cholesterol (LDL-C) Assay Kit (Direct Method-Sufactant Clearence Method)R1: 40ml×4 R2: 10ml×4box200
26HDL-CHigh Density Lipoprotein Cholesterol (HDL-C) Assay Kit (Direct Method-Select Inhibition Method)R1: 40ml×4 R2: 10ml×4box200
27ApoA-IApolipoprotein A-I (ApoA-I) Assay Kit (Immunoturbidimetric Method)R1: 30ml×4 R2: 10ml×4box160
28ApoBApolipoprotein B (ApoB) Assay Kit (Immunoturbidimetric Method)R1: 30ml×4 R2: 10ml×4box160
29LpaLipoprotein (a) (Lpa) Assay Kit (Immunoturbidimetric Method)R1: 30ml×2 R2: 10ml×2box80
30NEFANon-Esterified Fatty Acid (NEFA) Assay Kit (ACS-ACOD Method)R1: 30ml×2 R2: 10ml×2 (Calibrator:1ml×1,Control Level 1:1ml×1)box80
31CKCreatine Kinase (CK) Assay Kit (Phosphocreatine Substrate Method)R1: 40ml×4 R2: 10ml×4box200
32LDHLactate Dehydrogenase (LDH) Assay Kit (Lactate Substrate Method)R1: 40ml×4 R2: 10ml×4box200
33α-HBDHα-Hydroxybutyrate Dehydrogenase (α-HBDH) Assay Kit (α-Ketobutyric Acid Substrate Method)R1: 40ml×4 R2: 10ml×4box200
34HCYHomocysteine (HCY) Assay Kit (Enzymatic Cycling Method)R1: 40ml×2 R2: 10ml×2 (Calibrator:1ml×1, Control Level 1:1ml×1,Level 2:1ml×1)box100
35ASOAntistreptolysin O (ASO) Assay Kit (Latex-enhenced Immunoturbidimetric Method)R1: 40ml×2 R2: 10ml×2box100
36RFRheumatoid Factor (RF) Assay Kit (Latex-enhenced Immunoturbidimetric Method)R1: 40ml×2 R2: 10ml×2 (Calibrator:1ml×1,Control Level 1:1ml×1)box100
37CRPC-reactive Protein (CRP) Assay Kit (Latex-enhenced Immunoturbidimetric Method)R1: 30ml×2 R2: 10ml×2box80
38hs-CRPHigh Sensitive C-reactive Protein (hs-CRP) Assay Kit (Latex-enhenced Immunoturbidimetric Method)R1: 30ml×2 R2: 10ml×2box80
39IgAImmunoglobulin A (IgA) Assay Kit (Immunoturbidimetric Method)R1: 30ml×4 R2: 10ml×4box160
40IgGImmunoglobulin G (IgG) Assay Kit (Immunoturbidimetric Method)R1: 30ml×4 R2: 10ml×4 (Calibrator:1ml×1)box160
41IgMImmunoglobulin M (IgM) Assay Kit (Immunoturbidimetric Method)R1: 30ml×4 R2: 10ml×4 (Calibrator:1ml×1)box160
42CaCalcium (Ca) Assay Kit (Arsenazo III Method)R: 40ml×4box160
43CO2Bicarbonate (CO2) Assay Kit (PEPC Enzymatic Method)R: 40ml×4box160
44MgMagnesium (Mg) Assay Kit (Xylidyl Blue Method)R: 40ml×4box160
45FeIron (Fe) Assay Kit (Ferrozine Method)R1: 40ml×2 R2: 10ml×2box100
46PInorganic Phosphorus (P) Assay Kit (Phosphomolybdate Method)R: 40ml×4box160
Consumables
SNItemPack SizeUnitQty
1Calibration Serum Level 2(CAL 2)5*20mlbox100
2Human Assayed Multi-Sera5*20mlbox100
3Cuvette for IVC 120Pack of 10Pack1
4Cuvette for IVC 200Pack of 100Pack1
5R1 BottlePack of 100Pack1
6R2 BottlePack of 100Pack1
7Lamp—Pcs1
8Sample CupPack of 200Pack1
9Washing SolutionPack of 500 MLPack1
10Sample Probe—Pcs1
11Reagent Probe—Pcs1
12Washing Needle—Pcs1
13Sample Needle—Pcs1

Key Features

  • External & internal mirror polish, external & internal probe washing
  • Dedicated sampling probe equipped with sensitive liquid sensor, timely feedback
    of reagent & sample residuals
  • Collision protection, automatic probe depth adjusting
  • Teflon coating mixer. No water dropping (reducing carry-over)
  • Excellent mixing effect with standard mixing procedure
  • Permanent ceramic piston
  • Accurate dispensing as low as 0.1 μl
  • 80 reagent positions 
  • 40 sample positions
  • Non-stop cooling system with peltier pad inside, 24 hours 2℃-14℃
  • Bar code reader(optional)
  • 44 reaction cuvettes
  • Reaction volume as low as 150 μl
  • Stable & accurate temperature(37±0.1℃) for reaction
  • User friendly software interface simple, easy-to-operation
  • Sample automatic dilution(decrease, increase, normal)
  • Reaction result automatic checking and warning, calibration result automatic
    checking, warning alarm log
  • Linear & nonlinear calibration,Multi-points calibration up to 8 points
  • Quality control apply to westgard, L-T plot, cumulative

Get a Quote

Contact our team for pricing and availability of the IVC-200A.